Challenges
- Conducting a field survey to identify structural deficiencies at 22 buildings from a mining process
Solutions and Results
- Addressing over 850 issues/items requiring remediation actions.
- Providing recommendations and detail engineering for enhancements, repairs, and modifications.
- Provide remediation strategy and detail engineering to slabs, braces and roof structures deteriorated due to corrosion and thermal loads.
- Developing concepts for stairways, platforms, and structures.
- Evaluating actions for prioritization.
- Enhancing structures to comply with seismic standards following ASCE, ACI, AISC guidelines.
- Estimating an approximate CAPEX.